300/1-EK

Safety isolating transformers

300/1-EK
CLII safeisoP ce

Zastosowanie

Transformer for 12V lighting installation. Designed and tested according to norm EN61558-2-6. Separate windings, moulded in self-extinguishing Polyurethane and plastic capsulated. Insulation class II, double isolated. CE-marked. Short circuit and overload protected, non replaceable fuses. Supplied with 2m primary leads and secondary terminal connection for max. 10mm2. Dimmable with dimmers designed for inductive transformer loads. Transformer designed for 12V lighting installations, track or wiring systems.

 

Specyfikacja techniczna
300/1-EK
1
50 - 60 Hz
230 V
11,5 V
25,0 A
300 W
IP43
Wymiary
85 mm
150 mm
100 mm
3,75 kg
Informacje o zamówieniu
4-111-120301
5703451008520

Pliki do pobrania

 HP E

Rysunek wymiarowy

No dimension drawings available

Schemat połączeń


Produkty z tej kategorii
nazwa Numer artykułu moc Wtórny prądu Waga IP Zapas
105/1-EK 4-111-120101 105 W 9,1 A 1,45 kg IP43
200/1-EK 4-111-120201 200 W 16,0 A 3,25 kg IP43
300/1-EK 4-111-120301 300 W 25,0 A 3,75 kg IP43