LFA157-04

Autotransformers

LFA157-04
CLII autoP ce

Käyttökohde

Single-phase short circuit proof autotransformer designed and tested according to EN61558-2-13. Insulated windings moulded in self extinguishing Polyurethane and capsulated in plastic. For fixed installation, simple and easy mounting. Short circuit protected with glass tube fuse and overload protected with "cut out" fuse on primary side.
Portable autotransformer for changing system voltage.

Autotransformers are not able to eliminate earth faults, all earth fault problems will be propagated through the transformer, resulting in a considerable risk to safety. The use of autotransformers is therefore not permitted in ships and medical installations. Custom designed models on request.

 

Tekniset tiedot
LFA157-04
1
50 - -60 Hz
115 V
230 V
1,04 A
240 VA
IP20
Mitat
92 mm
155 mm
87 mm
2,6 kg
Tilaustiedot
4-058-120244
5703451002924

Ladattavat tiedostot

 LFA

Mittakuva

Ei mittakuvia saatavilla

Kytkentäkaavio

Ei kytkentäkaavioita saatavilla

Tuotteet tässä ryhmässä
Nimi Tuote n:o Teho Toisio virta Paino IP Varasto
LFA150-04 4-058-120154 150 VA 0,65 A 1,8 kg IP20
LFA157-04 4-058-120244 240 VA 1,04 A 2,6 kg IP20
LFA179-04 4-058-120484 480 VA 2,09 A 4,2 kg IP20
LFA193-04 4-058-121004 960 VA 4,17 A 7,8 kg IP20
LFA218-04 4-058-121804 1700 VA 7,4 A 15,1 kg IP20